[Abstract] We show that Swedish wind turbines constructed before 2007 lose 0.15 capacity factor percentage points per year, corresponding to a lifetime energy loss of 6%. A gradual increase of downtime accounts for around one third of the deterioration and worsened efficiency for the remaining. Although the performance loss in Sweden is considerably smaller than previously reported in the UK, it is statistically significant and calls for a revision of the industry practice for wind energy calculations. The study is based on two partly overlapping datasets, comprising 1,100 monthly and 1,300 hourly time series spanning 5–25 years each.
Jon Olauson, Division of Electricity, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden
Per Edström, Sweco Energuide, Gothenburg, Sweden
Jesper Rydén, Department of Mathematics, Uppsala University, Uppsala, Sweden
Wind Energy 2017; 20(12):2049–2053. DOI: 10.1002/we.2132
Download original document: “Wind turbine performance decline in Sweden”
This material is the work of the author(s) indicated. Any opinions expressed in it are not necessarily those of National Wind Watch.
The copyright of this material resides with the author(s). As part of its noncommercial educational effort to present the environmental, social, scientific, and economic issues of large-scale wind power development to a global audience seeking such information, National Wind Watch endeavors to observe “fair use” as provided for in section 107 of U.S. Copyright Law and similar “fair dealing” provisions of the copyright laws of other nations. Queries e-mail.
Wind Watch relies entirely on User Contributions |
![]() (via Stripe) |
![]() (via Paypal) |
Share:
Tags: Wind power, Wind energy